Generators

Tow Plant Generators Day Rate
Litepower 60KW/500A Generator $550.00

All generators include full fuel tank (and refill container if appropriate) and must be returned fully fueled. Refueling charges may be applied. Ask if you have ANY questions regarding refueling.

Movie Quiet® 60KW Generator 500 Amps Prime Power @ 120 Volts

Less is more has never been truer. 25% smaller, as much as 2000 pounds (907 kg) lighter and delivers a full 500 amps in both single and three phase. Can be towed with any half-ton vehicle. In production for over 10 years.

Voltage RegulatorGenerator
Lima/Marathon MagnaPLUS 94KW with Single Phase/Three Phase Switch. Provides full 500A@120V output in Single Phase and in Three Phase. Marine rated rectifier with surge suppression. CSA listed. Basler AVC63-7 with remote voltage adjustment. UL and CSA listed.

Circuit Breaker
250 amp breaker protects equipment in either single or three phase. Weather-proof glass cover. UL and CSA listed.

Electrical Connection
2 rows of UL listed Cam-Lok type connectors with male and female grounds. 2 Edison 20A outlets with separate breakers provided for convenience outlets. Engine block heater connection. NEC approved panel.

Size/Weight
With Trailer: Length: 154?, Width: 86?, Height: 72?
Without Trailer: Length: 96?, Width: 36?, Height: 50?
Weight: Trailer, generator, and fuel: 3500 lbs. (1590 kg)
Weight: Generator and fuel: 3000 lbs. (1363 kg)

Fuel Tank
60 Gallon tank is standard.

Noise Level
Less than 50 db(A) @ 50 feet.

Loads and Runtimes
500A - 14:45
375A - 18:45
250A - 25:20
125A - 42:00

Less Information.

Litepower 20KW/167A Generator $275.00

All generators include full fuel tank (and refill container if appropriate) and must be returned fully fueled. Refueling charges may be applied. Ask if you have ANY questions regarding refueling.

Movie Quiet® 20KW Generator (167 Amps Prime Power @ 120 Volts)

Engine
Lister-Petter LPW4 turbocharged 4 cylinder diesel. Meets EPA Mobile Off Highway, California CARB requirements.

Frequency Control
Barber-Colman electronic actuator with “True Crystal Technology”. For the first time, frequency is actually referenced to a quartz crystal!

Controller
Engine control, AC monitoring, fault and pre-fault systems are provided by a microprocessor-based system. All readouts are digital and are listed below. Weather-proof glass cover.

Generator
Stamford/Newage 22.3 single phase. 120-240V

Voltage Regulator
Newage SX460 with remote voltage adjustment.

Weight
Generator (w/fluids), tank (full) and trailer: 2036 lbs. (925 kg)
Tongue weight generator (w/fluids), tank (1/2 full): 242 lbs. (110 kg)

Dimensions
Generator, trailer and fuel tank 115"L 60"W 60"T

Fuel Tank
31 Gallon base mount.

Noise Level
Less than 50 dB(A) at 50 feet.

Circuit Breaker
90 Amp. UL and CSA listed.

Electrical Connection
UL listed, Cam-Lok E 1016 output panel with male and female ground. 1 Edison 20A duplex with 20A breaker provided for convenience outlet. NEC approved panel.

Less Information.

Tow Plant Genny Distro Packages Day Rate
Small - (120V) Generator Distro Package $225.00

A Basic Distro Package for your basic power needs.

Less Information.

Small - (220V) Generator Distro Package $235.00

A Basic Distro Package for your basic power needs.

Less Information.

Large - (220V) Generator Distro Package $550.00

A Large Distro Package for larger power needs.

Less Information.

Small Tie-in Package $ Call
Portable Put Put Generators Day Rate
Honda Eu2200i 15A Gen Set $100.00
Honda EU7000is 45.8A Gen Set $175.00

All generators come fully fueled up and include an empty gas can. The generator must be returned fully fueled or refueling charges will be applied. Ask if you have ANY questions regarding refueling.

Honda EU7000is

What’s “Clean Power”?
Computers and power-sensitive equipment require “clean power.” Clean power is electrical current that is consistent and has a stable signal, or sine wave. Honda inverter technology means stable, clean power in a smaller, lighter package. You can even operate the most sensitive electronics without fear of interruption.

Engine
Honda GX390 EFI

Displacement
389cc

AC Output
120/240V 7000W max. (58.3/29.1A) 5500W rated (45.8/22.9A)

Receptacles
20A 125V GFCI Duplex (2), 30A 125V Locking Plug, 30A 125/250V Locking Plug

Starting System
Recoil, electric

Fuel Tank Capacity
5.1 gal.

Run Time per Tankful
6.5 hrs.@ rated load, 18.0 hrs. @ 1/4 load

Dimensions
(L x W x H) 33.4" x 27.6" x 28.4"

Noise Level
60 dB(A) @ rated load, 52 dB(A) @ 1/4 load

Dry Weight
261 lbs.

Less Information.

Honda EU3000is 23.3A Gen Set $120.00

All generators come fully fueled up and include an empty gas can. The generator must be returned fully fueled or refueling charges will be applied. Ask if you have ANY questions regarding refueling.

Honda EU3000is

What’s “Clean Power”?
Computers and power-sensitive equipment require “clean power.” Clean power is electrical current that is consistent and has a stable signal, or sine wave. Honda inverter technology means stable, clean power in a smaller, lighter package. You can even operate the most sensitive electronics without fear of interruption.

Engine
196cc Honda GX200

AC Output
120V 3000W max.(25A) 2800W rated (23.3A)

Receptacles
20A 125V Duplex, 30A 125V Locking Plug

DC Output
12V, 144W (12A)

Starting System
Recoil, electric

Fuel Tank Capacity
3.4 gal.

Run Time per Tankful
7.1 hrs. @ rated load, 20 hrs. @ 1/4 load

Dimensions
25.9" x 17.6" x 22.0"

Noise Level
58 dB(A) @ rated load, 49 dB(A) @ 1/4 load

Dry Weight
131 lbs.

Less Information.

Honda EU2000i 13.3A Gen Set $100.00

All generators come fully fueled up and include an empty gas can. The generator must be returned fully fueled or refueling charges will be applied. Ask if you have ANY questions regarding refueling.

Honda EU2000i

What’s “Clean Power”?
Computers and power-sensitive equipment require “clean power.” Clean power is electrical current that is consistent and has a stable signal, or sine wave. Honda inverter technology means stable, clean power in a smaller, lighter package. You can even operate the most sensitive electronics without fear of interruption.

Engine
Honda GX100

Displacement
98.5cc

AC Output
120V 2000W max. (16.7A) 1600W rated (13.3A)

Receptacles
20A 125V Duplex

DC Output
12V, 96W (8A)

Fuel Tank Capacity
.95 gal

Run Time per Tankful
3.4hr @ rated load 8.1 hrs @ 1/4 load

Dimensions
20.2" x 11.4" x 16.7"

Noise Level
59 dB(A) @ rated load 53dB(A) @ 1/4 load

Dry Weight
45.6 lb.

Less Information.

Generator Accesories Day Rate
220V Bates to Twistlock Adapter $ Call
25' Grounding Rod Extension Cable $10.00
60KW Load Bank $75.00

60KW Load Bank

The LitePOWER 60KW Load Bank was designed to test generators for fuel flow, cooling and general operation at full load. It is small, portable, quiet, and simple to operate. One required for LitePOWER 60KW, 2 for 140KW and 3 for 220KW.

Operation: There are just four switches, each controls 25% of the load.
Output: 500 amps @ 120 volts AC or DC three phase, 333 amps @ 120 volts AC or DC single phase.
Electrical Connection: UL listed, Cam-Lok E1016 connectors.
Size: Length: 30?, Width: 30?, Weight: 150 lbs. (68 kg).

Less Information.